Eagle enet io Application
From Manuals
Eagle SBC enet_io Application
The Eagle Single Board Computer's (SBC) with Ethernet are shipped with the enet_io example application from the TI Stellarisware Library. This example application demonstrates web-based I/O control using the Ethernet controller and the lwIP TCP/IP Stack. DHCP is used to obtain an Ethernet address. If DHCP times out without obtaining an address, a static IP address will be chosen using AutoIP. The address that is selected will be shown on COM1, allowing access to the internal web pages served by the application via a normal web browser. Figure 2.1 shows the web page that will first be displayed.
In order to demonstrate this application on an Eagle SBC without the optional USB Debug Port you will need the following software and equipment:
- 1. A Personal Computer (PC) with a serial port or a USB to serial port adapter
- 2. A DB9 to 2x5 adapter cable if using an Eagle SBC where COM1 is a 2x5 pin header
- 3. A null modem cable
- 4. A terminal program such as Putty, HyperTerminal, or TeraTerm
- 5. A web browser
- 6. One Ethernet cable
- 7. One +5V power supply
Please follow these steps to run the enet_io application on an Eagle SBC without the optional USB Debug Port:
- 1. If the Eagle SBC's COM1 port to the computer using the null modem cable. NOTE: Use the 2x5 adapter cable if COM1 is a 2x5 pin header.
- 2. Connect the Eagle SBC's Ethernet port to an Ethernet Network.
- 3. Start and set-up the terminal program with the following settings.
- a. Baudrate – 115200
- b. Data Bits – 8
- c. Parity – None
- d. Stop Bits – 1
- e. Flow Control – None
- 4. Apply power to the board.
- 5. The Eagle SBC will transmit the boards IP address to the terminal
- 6. Open a web browser.
- 7. Type the IP address into the web browsers address bar and the web page in Figure 2.1 should load.
- 8. Click on “I/O Control Demo 1 (HTTP Requests)”.
- 9. Click on the “Toggle LED” button to turn the User LED on.
In order to demonstrate the enet_io application on an Eagle SBC with the optional USB Debug Port you will need the following software and equipment:
- 1. A Personal Computer (PC) with a USB port
- 2. A terminal program such as Putty, HyperTerminal, or TeraTerm
- 3. A web browser
- 4. One USB A to micro USB cable (Supplied with Eagle SBC with USB Debug Port)
- 5. One Ethernet cable
Please follow these steps to run the enet_io application on an Eagle SBC with the optional USB Debug Port:
- 1. Make sure two jumpers are set correctly to enable power to come from the Debug port and enable the virtual COM port. The Eagle 50 jumpers are JP1 for power and and JP6 for the virtual COM port.
- 2. Connect the Eagle SBC's Ethernet port to an Ethernet Network.
- 3. Connect the Eagle SBC to the PC by using the USB A to micro USB cable.
- 4. Wait until the USB drivers have been installed. The USB drivers can be found in the Software Updates section on the Eagle's Wiki. http://wiki.micromint.com/index.php/Eagle_Documentation
- 5. Find out what COM port the Eagle SBC's virtual COM port is by looking in Windows Device Manager’s PORTS (COM & LPT). The Eagle SBC's COM port is the one that says Stellaris Virtual COM Port.
- 6. Start and set-up the terminal program for the COM port that the Eagle SBC is on and with the following settings.
- a. Baudrate – 115200
- b. Data Bits – 8
- c. Parity – None
- d. Stop Bits – 1
- e. Flow Control – None
- 7. Press the Reset button.
- 8. The Eagle SBC will transmit the boards IP address to the terminal.
- 9. Open a web browser.
- 10. Type the IP address into the web browsers address bar and the web page in Figure 2.1 should load.
- 11. Click on “I/O Control Demo 1 (HTTP Requests)”.
- 12. Click on the “Toggle LED” button to turn the User LED on.