Lincoln-60 Manual/Mechanical and Electrical Characteristics
From Manuals
Absolute Minimum and Maximum Ratings
| Characteristic | Minimum | Maximum | Unit |
| Voltage on J1 without LCD | 3.9 | 5.8 | VDC |
| Voltage on J1 with LCD | 4.8 | 5.8 | VDC |
| Voltage on VBAT (B1 or J12) | 2.1 | 3.6 | VDC |
| Voltage on ADC | 0.0 | 3.3 | VDC |
| Voltage on Digital Input | 0.0 | 5.0 | VDC |
| Operating Temperature | 0 | 70 | ºC |
| Storage Temperature | -50 | 125 | ºC |
The Lincoln 60 SBC is currently available for commercial temperature ranges. Contact the Micromint sales department if you require support for industrial temperature ranges.
Supply Current Versus System Clock Frequency
Test Conditions: Vin (J1) = 5.63V, VCC = 3.3V
Mechanical Dimensions
Below is the physical dimensions for the Lincoln 60. The mounting holes will accept a #4 size screw.
| DIM | Inches | Millimeters | DIM | Inches | Millimeters | DIM | Inches | Millimeters | DIM | Inches | Millimeters |
| A | 3.94 | 100.0 | G | 0.266 | 6.75 | M | 0.71 | 18.03 | S | 2.835 | 72.0 |
| B | 0.116 | 2.95 | H | 0.275 | 6.98 | N | 0.58 | 14.73 | T | 0.115 | 2.92 |
| C | 0.851 | 21.61 | I | 0.124 | 3.14 | O | 0.369 | 9.37 | U | 0.895 | 22.73 |
| D | 0.567 | 14.4 | J | 0.4 | 10.16 | P | 0.117 | 2.97 | V | 0.3 | 7.62 |
| E | 0.828 | 21.03 | K | 0.265 | 6.74 | Q | 0.12 | 3.04 | W | 0.608 | 15.44 |
| F | 0.2 | 5.08 | L | 0.63 | 16.0 | R | 0.950 | 24.13 | X | 0.76 | 19.3 |
| DIM | Inches | Millimeters | DIM | Inches | Millimeters | DIM | Inches | Millimeters | DIM | Inches | Millimeters |
| A | 0.33234 | 8.4415 | F | 0.588 | 14.935 | K | 0.261 | 6.63 | P | 0.136 | 3.45 |
| B | 0.3543 | 9.0 | G | 0.072 | 1.8171 | L | 0.06 | 1.524 | Q | 0.269 | 6.83 |
| C | 0.117 | 2.97 | H | 0.56693 | 14.40 | M | 0.545 | 13.843 | R | 0.177 | 4.5 |
| D | 0.345 | 8.763 | I | 0.072 | 1.83 | N | 0.1 | 2.54 | S | 0.256 | 6.5 |
| E | 0.599 | 15.21 | J | 0.63 | 16.0 | O | 0.288 | 7.313 |